CCPRO

Thursday, 25.04.2024, 21:34

Welcome Guest | RSS

RUSSIAN RUSSIAN VERSION VERSION

English Russian Translation Services English Russian translation - File CatalogRegistrationLogin
Site working-days
Map of visits
Site menu
3D Cloud tags
Bookmark for site

If you want to add this page to socially mark, click on this button. In the appearing window, locate and click «None», then select the social network and in the upper right corner click «Submit».

Section categories
English Russian translation of technical manual (only English Russian text) [22]
English Russian translation of Standards (only English Russian text) [5]
English Russian translation of Directives (only English Russian text) [1]
English Ukrainian translation of Directives (only English Ukrainian text) [1]
Search
Site friends
  • Create your own site
  • Statistics

    Total online: 1
    Guests: 1
    Users: 0
    Block title
    gages - english russian translate matter of safety photohelic switch - english russian translate intelisys-english russian translate professional translation engine-english russian translate turbocharged engines 1300 series automatic voltage regulator avr-english russian translate technical documentation technical documents fault finding for stamford ac ac generator gen - english russian translate battery electric forklift truck multipurpose forklift truck bypass valve valve - english russian translate intake air systems piston type accumulator twin screw pump chain hoist hoist - english russian translate cuttings re-Injection fabric expansion goints controller MCS II thyristor power controller inlet casing Compressor combustor turbine cylinder exhaust diffuser exhaust manifold british standard 5486-12:1989 bs 5486-12:1989 british standard 3135:1989 bs 3135:1989 european standard PrEN 15038:2006(E european directive - atex 94/9/ec
    Russian Translation Services » English Russian translation - File Catalog » English Russian translation of technical manual (only English Russian text)

    Controller InteliSys - English Russian Translation Technical Manual
    [ Download English Russian translation as a zipped PDF-file with two pages (145.8 Kb) ] 24.01.2010, 23:54
    Following is the English Russian translation of Controller InteliSyss Technical Manual page. By clicking on the link above, "[Download English Russian translation as a zipped PDF-file with two pages (....... Kb)]" you can download file in PDF format with image which is located on webpage "TECHNICAL TRANSLATION  --    MODULAR GEN-SET CONTROLLER INTELISYS MADE BY ComAp, spol. s r.o." but with the ability to copy English Russian translation of the text.

    English Russian translation of manual pages as plain text

    ENGLISH RUSSIAN TECHNICAL TRANSLATION OF CONTROLLER INTELISYS MANUAL
     



    In this case InteliSys synchronizes gen-set to mains, closes GCB, Breaker overlap time runs in parallel and then opens MCB.
    В случае если InteliSys синхронизирует генераторную установку с энергосетью, замыкается АВГ и по истечению времени работы на параллельном режиме, которое определено уставкой BreakerOverlap, расцепляется САВ.

    When the mains recovers gen-set remains island running !
    Когда электроснабжение от сети восстанавливается, генераторная установка продолжает работать автономно!

    4. To stop the gen-set select other mode than TEST
    4. Остановить генераторную установку в режиме ТЕСТИРОВАНИЯ (TEST mode) невозможно. Для остановки генераторной установки необходимо выбрать другой режим.

    While TEST mode is selected, gen-set is running unloaded.
    В режиме ТЕСТИРОВАНИЯ (TEST mode) генераторная установка работает без нагрузки.

    When power cut comes InteliSys opens MCB.
    Когда прекращается подача электроэнергии из сети, InteliSys расцепляет MCB (САВ).

    After Return break elapses, InteliSys closes GCB.
    После истечения задержки по времени, которое определено уставкой Return break, InteliSys замыкает АВГ.

    When the mains recovers:
    При восстановлении подачи электроэнергии от сети происходит следующее:

    1. After the MainsReturn del InteliSys starts back synchronizing to mains and closes MCB.
    1. После задержки по времени, которое определено уставкой Mains Ret del, InteliSys снова начинает синхронизацию с энергосетью и замыкает MCB (САВ).

    2. The gen-set remains running in parallel for BreakerOverlap time, opens GCB and remain running unloaded.
    2. Генераторная установка продолжает работать на параллельном режиме, в течение определенного времени, которое установлено уставкой BreakerOverlap, GCB (АВГ) размыкается, а генераторная установка продолжает работать без нагрузки.

    To stop the gen-set select other mode than TEST
    Остановить генераторную установку в режиме ТЕСТИРОВАНИЯ (TEST mode) невозможно. Для остановки генераторной установки необходимо выбрать другой режим.

    Hint:
    Подсказка:

    InteliSys does not respond to GCB ON/OFF , STOP, START in Ret from test = AUTO.
    Если уставка Ret from test = AUTO, InteliSys не реагирует на нажатие кнопки GCB ON/OFF (АВГ ВКЛ/ВЫКЛ), кнопок STOP или START.

    Engine automatically starts, when TEST mode is selected.
    Двигатель автоматически запускается, когда выбран режим ТЕСТИРОВАНИЯ (TEST mode).

    Engine can start automatically without warning when pressing FAULT RESET after shut down alarm.
    Двигатель может запуститься автоматически, без предупреждения при нажатии кнопки FAULT RESET после квитирования неисправности.

    Load control modes in parallel to mains
    Способы регулирования нагрузки на параллельной работе с энергосетью

    Baseload
    Базисная нагрузка (Baseload)

    Process control: Load CTRL PTM = BASELOAD
    Присвоить значение уставке Load CTRL PTM в группе Process control значение BASELOAD (Process control: Load CTRL PTM = BASELOAD)

    Genset power is kept on value given by Baseload setpoint.
    Мощность генераторной установки будет определяться значением уставки Baseload.

    Internal Import export
    Внутреннее потребление-выдача реактивной мощности (Internal Import export)

    ProcessControl: Load CTRL PTM = IMP/EXP
    Присвоить значение уставке ProcessControl: Load CTRL PTM = IMP/EXP

    Process control: IE measurement = IM3 CT INPUT
    Присвоить значение уставке Process control: IE measurement = IM3 CT INPUT

    Genset load is controlled to keep the import load at the level given by setpoint Process control: Import load value.
    Контролировать потребление реактивной мощности нагрузкой на заданном уровне необходимо с помощью уставки управления нагрузкой генераторной установки Process control: Import load value.

    InteliSys measures Import/Export value via CT connected to In/Im3 terminals.
    InteliSys измеряет значения потребления/выдачи реактивной мощности через трансформатор тока, который подсоединен к зажимам In/Im3

    External Import export
    Внешнее потребление-выдача реактивной мощности (External Import export)

    Process control: Load CTRL PTM = IMP/EXP
    Присвоить значение уставке Process control: Load CTRL PTM = IMP/EXP

    Process control: IE measurement = ANALOG INPUT
    Присвоить значение уставке Process control: IE measurement = ANALOG INPUT

    Genset load is controlled to keep the import load at the level given by setpoint Process control: Import load value.
    Контролировать потребление реактивной мощности нагрузкой на заданном уровне необходимо с помощью уставки управления нагрузкой генераторной установки Process control: Import load value.

    Real I/E power value is measured from the Analog input LdCTRL:ExtI/E.
    Реальное значение мощности I/E измеряется на аналоговом входе сигнала LdCTRL:ExtI/E.

    Temperature control by gen-set power
    Температурное регулирование мощности генераторной установки (Temperature control by gen-set power)

    Genset load is changed to keep required temperature TempByPwr Treq on analog input LdCtrl:TByPwr.
    В связи изменением нагрузки генераторной установки, для удержания требуемой температуры установки ее значение надо присвоить уставке TempByPwr Treq измерение которой осуществляется на аналоговом входе сигнала LdCtrl:TByPwr.

    If the temperature measured from analog input "LdCtrl:TbyPwr” exceeds value TbyPwr Treq the gen-set power is decreased gradually to Min Power PtM.
    Если температура, измеренная от аналогового входного сигнала, "LdCtrl:TbyPwr" превышает значение уставки TbyPwr Treq, мощность генераторной установки постепенно уменьшается до значения установленного уставкой Min Power PtM.

    If the temperature drops below TbyPwr Treq the gen-set increases the power gradually up to Nominal power
    Если температура становится ниже значения уставки TbyPwr Treq, генераторная установка постепенно увеличивает мощность до номинальной мощности генератора, численное значение которой присвоено уставке Nominal power

    Hint:
    Подсказка:

    Sampling time of Temperature by power control loop is 20 seconds.
    Время выборки температуры контура регулирования мощности - 20 секунд.

    Requested power value ActReqPower is visible on the controller measure screen.
    Значение требуемой мощности - ActReqPower видима на экране контроллера в окне измерения.

    Decreasing of Requested gen-set power according to TbyPwr control (does not decrease Nominal power value) has no influence on generator protection limits (different from Power derating function).
    Уменьшение требуемой мощности генераторной установки согласно настройке управляющей функции TbyPwr (не уменьшает значение номинальной мощности) не влияет на защиту генератора (в отличие от функции Power derating).

    Overheat protection
    Защита от перегрева (Overheat protection)

    Function is active when ProcessControl:Overheat prot = ENABLED
    Функция активна, когда ей присвоено значение - ЗАДЕЙСТВОВАНО (ENABLED)
    Синтаксис: ProcessControl:Overheat prot = ENABLED

    Analog input: LdCtrl:TbyPwr
    Аналоговый вход: LdCtrl:TbyPwr

    Setpoints: Same as described in previous paragraph ( temperature by power control)
    Уставки: Такие же, как описано в предыдущем параграфе «Температурное регулирование мощности генераторной установки»

    The function is similar to the Temp by Power. But in this case the requested load can vary between Mim Power PtM and Baseload (if Load control = BASELOAD).
    Функция Overheat protection подобная функции Temp by Power. Но в этом случае требуемая нагрузка может изменяться между значениями Mim Power PtM и Baseload (если уставке Load control присвоено значение BASELOAD.
    Синтаксис:
    Load control = BASELOAD.

    Hint:
    Подсказка:

    Requested temperature should be set a bit higher as operational temperature.
    Требуемая температура должна быть установлена немного выше, чем рабочая температура.
     

    ENGLISH RUSSIAN TECHNICAL TRANSLATION OF CONTROLLER INTELISYS MANUAL

    English Russian translation of manual pages as plain text


    Category: English Russian translation of technical manual (only English Russian text) | Added by: tr | Tags: intelisys-english russian translate
    Views: 1549 | Downloads: 436 | Comments: 1 | Rating: 0.0/0
    Total comments: 0
    Name *:
    Email *:
    Code *:
    Login form
    Tag list
    Site friends
  • Create your own site
  • Map of visits
    Copyright CCPRO Ltd © 2024

    Free article submission AllofMaine.com   Website Monitoring by InternetSeer